Communication Manager Maintenance-Object Repair Procedures
710 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Figure 36: ISDN-BRI Set Interactions
This section contains the ISDN-BRI Set, ASAI Adjunct and Avaya Adjunct Maintenance
documentation. Some of the results of maintenance testing of the ISDN-BRI Set or the ASAI
and Avaya Adjunct may be affected by the health of the ISDN-BRI circuit pack and port. These
interactions should be kept in mind when investigating the cause of ISDN-BRI Set problems.
Hardware Error Log Entries and Test to Clear Values
BRI Line
Circuit Pack
P
O
R
T
D-Channel
B-Channel
B-Channel
PHYSICAL CONNECTION
VOICE
or DATA
SET
Logical Connection
VOICE
or DATA
SET
PBX
Physical Connection
Table 240: BRI-SET/ASAI-ADJ Error Log Entries
Error
Type
Aux
Data
Associated
Test
Alarm
Level
BRI-SET
BRI-DAT
Alarm
Level
ASAI-ADJ
ATT-ADJ
ATTE-AJ
LGATE-AJ
On/ Off
Board
Test to Clear Value
0 (a
) 0 Any Any Any Any test station ext r 2
test data-module ext r 2
2 (b
)2-102None
18 0 busyout
station ext
WRN MAJ
WRN
1
OFF release station ext
130 (c
)WRNONtest port PCSS sh
1 of 2