SNI-BD (SNI Circuit Pack)
Issue 1 June 2005 2105
2100 ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2300 ABRT The downlink message necessary to run this test could not be sent.
1. Retry the command at 1-minute intervals up to 3 times.
2301 ABRT The software timer could not be set before sending the downlink message
necessary to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2306 ABRT The SNI circuit pack is not responding to test requests sent by software.
1. Run the test led switch-node for the switch node where the SNI
resides to verify whether the LEDs on the board light.
2. If the LEDs on the other boards in the carrier light, but the LEDs on this
board do not light, run test 760 using test board location l for
the active SNC in this carrier. Wait 5 minutes and then try step 1 one
more time. If the LEDs on this board still do not light, replace this
board. Replacing an SNI may be service interrupting. See SNI-BD
(SNI Circuit Pack) on page 2046 for the procedure for replacing an
SNI.
3. If none of the LEDs light for the boards in the same carrier as this
board, fix any problems associated with the connectivity of this carrier
to the server.
a. Check list fiber-link to see the fiber connections to this
carrier.
b. Check the LEDs on every SNI and EI, and fix any fiber problems.
c. Enter display errors, and follow the repair procedures for any
EXP-INTF error entries associated with the controlling IPSI
connected PN.
d. Follow the repair procedures for any SYNC, SNI-BD, SNC-BD,
FIBER-LK, or SNI-PEER error entries.
4. Follow the procedure described above, SNI Manual Loopback to
determine whether the circuit pack or the fiber connection is faulty.
Table 755: TEST #777 Failure Audit (continued)
Error
Code
Test
Result
Description / Recommendation