HYB-LINE (Hybrid Line)
Issue 1 June 2005 1341
Hybrid Line Local Digital Loop-Around Test (#58)
This test checks the control channel between the media server and the port’s digital circuitry.
The media server sends transparent data to the on-board microprocessor and compares the
data echoed back. This test is repeated three times.
Table 468: Test #58 Hybrid Line Local Digital Loop-Around Test
Error
Code
Test
Result
Description / Recommendation
ABRT Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
1000 ABRT System resources required to run this test are not available. The port may
be busy with a valid call.
1. Use display port location to determine the station extension
number of the port. Use status station to determine the service
state of the port. If the port is in use, wait until it is idle before testing.
2. If the port status is idle, then retry the command at 1-minute intervals up
to 5 times.
1004 ABRT The port was seized by a valid call during the test. The test has been
aborted.
1. Use display port location to determine the station extension
number of the port. Use status station to determine the service
state of the port. If the port is in use, wait until it is idle before testing.
2. Retry the command at 1-minute intervals up to 5 times.
2000 ABRT Response to the test was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
1 of 2