Communication Manager Maintenance-Object Repair Procedures
1562 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Error Log Entries and Test to Clear Values
Notes:
a. Error Type 0: r
un the short test sequence first. If every test passes, run the long test sequence. Refer to
each test’s description and follow its procedures.
Table 576: MET Line Error Log Entries
Error
Type
Aux
Data
Associated Test Alarm
Level
On/Off
Board
Test to Clear Value
0 (a) 0 Any Any Any test port location sh r 1
1 (b
) 40987 None
18 (c
)0 busyout port
location
WRN OFF release port location
130 (d
) None WRN ON test port location sh
257 (e
) 40988 None MIN
WRN
1
1. Major or Minor alarms MO can be downgraded to Warning based on the values in set options.
OFF
513 (f
) 40965 Hybrid Line
Station Audits
(#61)
WRN OFF test port location sh r 4
769 Port Diagnostic
test (#35)
MIN
WRN
1
ON test port location l r 3
1025 Hybrid and Conf.
Circuits (#57)
MIN
WRN
1
ON test port location l r 3
1537 (g
) 40968 None MIN
WRN
1
OFF
1793 TDM NPE
Crosstalk test
(#6)
MIN
WRN
1
ON test port location l r 3
2049 (h
) 32770
2049 (h
) 40967
3840 (i
) 40989