Communication Manager Maintenance-Object Repair Procedures
2538 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Any NO
BOARD
The test could not relate the internal ID to the port (no board).
This could be due to incorrect translations, no board is inserted,
an incorrect board is inserted, or an insane board is inserted.
1. Ensure that the board translations are correct. Execute the
add ds1 location command to administer the board
interface if it is not already administered.
2. If the board was already administered correctly, check the
error log to determine whether the board is hyperactive. If
this is the case, the board is shut down. Reseating the
board will re-initialize the board.
3. If the board was found to be correctly inserted in step 1,
then enter the busyout board location.
4. Enter the reset board location.
5. Enter the release board location.
6. Enter the test board location long.
This should re-establish the linkage between the internal ID and
the port.
Table 903: Test #36 Port Audit and Update Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 2