Communication Manager Maintenance-Object Repair Procedures
2310 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Any FAIL This test can fail due to either on- or off-board problems. Off-board
problems of concern include EXP-PN, EXP-INTF, or RMC-ENV faults,
TDM-BUS faults, and faults associated with the tone detectors/tone
generators. Clear every off-board problem before replacing the board.
Keep in mind that a TDM-BUS problem is usually the result of a faulty
board connected to the backplane or bent pins on the backplane.
1. Resolve any EXP-PN, EXP-INTF, or RMC-ENV errors.
2. Resolve any TDM-BUS errors.
3. Resolve any TONE-BD and/or TONE-PT errors.
4. Test the board when the faults from steps 1, 2, and 3 are cleared.
Replace the board only if the test fails.
PASS The port is correctly using its allocated time slots. User-reported troubles
on this port should be investigated using other port tests and examining
station, trunk or external wiring.
0NO
BOARD
The test could not relate the internal ID to the port (no board).
1. Verify that the board’s translations are correct. Translate the board, if
necessary.
2. Enter busyout board location.
3. Enter reset board location.
4. Enter release board location.
5. Enter test board location long.
This should re-establish the linkage between the internal ID and the port.
Table 829: Test #6 NPE Crosstalk Test (continued)
Error
Code
Test
Result
Description / Recommendation