ANL-16-L (16-Port Analog Line)
Issue 1 June 2005 395
Station Status and Translation Audits and Updates Test (#36)
This test updates the analog port’s message lamp state (if it has one) and translations with
information in the software.
Table 116: Test #36 Station Status and Translation Audits and Updates
Error
Code
Test
Result
Description / Recommendation
ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1004 ABRT The port was seized by a valid call during the test. The test has been
aborted.
1. Use display port location to determine the station extension.
Use status station to determine the service state of the port. If the
port is active, wait until it is idle.
2. Retry the command at 1-minute intervals up to 5 times.
3. If the test continues to abort and the port is not in use, escalate the
problem.
1005 ABRT The test was aborted due to a configuration problem. This test may not be
applicable, or it may be disruptive to terminal equipment other than a voice
terminal (for example, the modem pool member or Music On Hold).
1006 ABRT This port has been busied out by command, or taken out-of-service by the
failure of the NPE Crosstalk test.
1. Look in the error log for error type 18 (port busied out) for this port. If
this error is present, release the port with release station
extension, and run the test again.
2. Check the error log for error type 1025 (NPE crosstalk test failed) for
this port. If this error is present, investigate the errors associated with
the NPE Crosstalk test (#6).
3. Make sure that the terminal is connected and in service, and then
retest.
2000 ABRT Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals up to 5 times.
2100 ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.