PE-BCHL (PRI Endpoint Port)
Issue 1 June 2005 1781
System Technician-Demanded Tests:
Descriptions and Error Codes
Investigate tests in the order presented. By clearing Error Codes associated with the NPE
Crosstalk test (#6), you may also clear errors generated from other tests in the sequence.
Table 657: PE-BCHL - Error 3585 Aux Data Values
Aux
Data
Meaning
10 A call in a stable, talking state (the active state) was cleared
unexpectedly by the far-end terminal adapter with an ISDN RESTART
message.
4
7
8
260
263
A call that has not reached the active state, but has at least reached a
ringing state, was cleared unexpectedly by the far-end terminal adapter
with an ISDN RESTART message.
1
3
6
265
A call that has not yet reached a ringing state was cleared unexpectedly
by the far-end terminal adapter with an ISDN RESTART message.
11
12
19
267
268
531
A call that was already in the process of clearing has been cleared by the
far-end terminal adapter with an ISDN RESTART message. If this
condition occurs frequently, it may mean that the far-end terminal adapter
is attempting to clear ports that it thinks are in a “hung” state. The
RESTART message puts the port in an idle condition.
Order of Investigation Short Test
Sequence
Long Test
Sequence
D/ND
1
1. D = Destructive; ND = Nondestructive
NPE Crosstalk test (#6) X ND
Conference Circuit test (#7) X ND
Audit and Update test (#36) X X ND
Signaling Link State Check test (#255) X X ND
Service State Audit test (#256) X X ND
Call State Audit test (#257) X X ND