Communication Manager Maintenance-Object Repair Procedures
1272 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
116 FAIL The SNI circuit pack (Endpoint 1) cannot communicate with the equipped
SNI in slot 16. Use list fiber-link to see a fiber link’s endpoints.
1. Perform the Fiber link fault isolation
in Chapter 4: General
troubleshooting in Maintenance Procedures (03-300192). This should
resolve multiple SNI-PEER errors.
2. If the SNI being tested has SNI-PEER Error Type 2817, replace the
SNI being tested. (Replacing an SNI may be service interrupting.
Refer to the SNI-BD section for the procedure to replace an SNI.) To
view SNI-PEER errors, use display errors with category
PNC-PEER. Retry the command.
3. If the SNI being tested still has SNI-PEER Error Type 2817, replace
the SNI in slot 16.
117 FAIL The SNI circuit pack (Endpoint 1) cannot communicate with the equipped
SNI in slot 17. Use list fiber-link to see a fiber link’s endpoints.
1. Perform the Fiber link fault isolation
in Chapter 4: General
troubleshooting in Maintenance Procedures (03-300192). This should
resolve multiple SNI-PEER errors.
2. If the SNI being tested has SNI-PEER Error Type 3073, replace the
SNI being tested. (Replacing an SNI may be service interrupting.
Refer to the SNI-BD section for the procedure to replace an SNI.) To
view SNI-PEER errors, use display errors with category
PNC-PEER. Retry the command.
3. If the SNI being tested still has SNI-PEER Error Type 3073, replace
the SNI in slot 17.
Table 440: Test #759 Configuration Audit (continued)
Error
Code
Test
Result
Description / Recommendation
8 of 22