Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
Communication Manager Maintenance-Object Repair Procedures
1204 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
1032 ABRT The EI cannot detect the framing signal and cannot run the test.
1. Refer to the errors for Test #238 to determine why the EI circuit pack is
out of frame.
1033 ABRT The EI circuit pack does not have a fiber link administered to it. There is
not sufficient data to run test.
1. Use list fiber-link to verify that there is no fiber link
administered to this circuit pack.
2. If there is no fiber administered to this circuit pack, but there should
be, use add fiber-link to add the correct fiber.
3. Retry the command.
1394 ABRT The EI circuit pack is out of service and the test cannot be run. This
condition is due to a change in the EI circuit pack’s ability to communicate
with the EI or SNI circuit pack on the other end of the fiber.
1. Run Test #237, and check the Error Log for EXP-INTF error type
1281. If error type 1281 is present or if Test #237 does not pass, see
repair procedures for Test #237, in Table 409: Test #237 Expansion
Interface Neighbor Query Test on page 1199.
1395 ABRT This test cannot be run on an EI circuit pack if it is part of the B-side PNC
and duplicated PNC is not enabled.
1. If this test needs to run on this EI circuit pack, use change
system-parameters duplication to enable PNC.
2. Use set pnc lock to prevent the system from doing a PNC
interchange.
3. Repeat this test.
2000 ABRT Response to the test was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 3 times.
2100 ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2500 ABRT Internal system error
1. Retry the command at 1-minute intervals up to 3 times.
Table 411: Test #240 Expansion Interface Local Looparound (continued)
Error
Code
Test
Result
Description / Recommendation
3 of 4