Communication Manager Maintenance-Object Repair Procedures
1220 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Table 415: Test #336 Expansion Interface Reset Test
Error
Code
Test
Result
Description / Recommendation
4 ABRT Could not reset the PN EI circuit pack over the optical fiber since the
neighbor EI circuit pack or SNI circuit pack is not recognized by software
(inserted).
1. Insert neighbor EI circuit pack or SNI circuit pack and perform reset
again.
1015 ABRT The system will not allow this test to be run because the EI circuit pack
has not been busied out.
1. Busyout the EI circuit pack. Enter reset board location.
2. Retry the command.
2000 ABRT Response to the test request was not received within the allowable time
period.
2100 ABRT Could not allocate the necessary system resources to run this test.
2500 ABRT Internal system error
1. Retry the command at 1-minute intervals up to 3 times.
1 FAIL The EI did not successfully reset.
1. If the EI circuit pack is in the PN, the PN’s Maintenance board may be
holding the EI circuit pack reset. Attempt to rectify this condition by
executing test maint P long on the Maintenance board in the
same PN.
2. If step 1 was not successful in releasing the EI circuit pack,
temporarily remove the PN’s Maintenance circuit pack.
3. Repeat reset board location.
4. If reset continues to fail, replace circuit pack.
5. Insert PN’s Maintenance circuit pack if it was removed.
2 FAIL The EI circuit pack was successfully reset, but it did not begin running
after the reset.
1. If the EI circuit pack is in the PN, temporarily remove the PN’s
Maintenance circuit pack.
2. Use reset board location.
3. Reinsert the PN’s Maintenance circuit pack if it was removed.