Communication Manager Maintenance-Object Repair Procedures
342 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
For ADM-CONN Errors
None of the Administered Connection Error Types have a specific associated test and, except
for errors 17 and 127, are valid only for administered connections established over ISDN-PRI
facilities. Error 127 is valid for administered connections established over non-ISDN facilities or
between two endpoints on the same switch.
Notes:
a. Error Types 1, 16, 22, 50, 52, 65, 66, 69, 88 are typically associated with administration
problems and are not expected to be temporary. The administered connection is not retried
and the failure is alarmed immediately. The alarm threshold specified by the customer is
ignored.
6, 21, 31, 127 (d
) Any None Any OFF None
16 (a
) Any None Any OFF None
17 (e
) Any None Any OFF None
18, 102 (f
) Any None Any OFF None
22 (a
, g) Any None Any OFF None
34, 42, 44, 58 (h
) Any None Any OFF None
38, 41 (i
) Any None Any OFF None
43, 81 Any None Any OFF None
50 (a
) Any None Any OFF None
52 (a
) Any None Any OFF None
54 Any None Any OFF None
65, 66, 69 (a
) Any None Any OFF None
82 Any None Any OFF None
88 (a
) Any None Any OFF None
91, 95, 96, 97, 98,
99, 100, 111
Any None Any OFF None
Table 92: Administered Connection Error Log Entries (continued)
Error
Type
Aux
Data
Associated Test Alarm
Level
On/Off
Board
Test to Clear
Value
2 of 2