RANL-STA (Remote Analog Line (Station) Port)
Issue 1 June 2005 1919
Notes:
a. Error Type 0: run the short test sequence first. If every test passes, run the long test
sequence. Refer to each test’s description, and follow its procedures.
b. Error Type 1: in-line errors, can only be resolved over time.
Aux Data 40960 indicates that too many simultaneous incoming ringing attempts were
made on this board. Only 4 ports on a board may ring simultaneously. A 5th incoming call
will cause an inline error from the board.
Aux Data 40975 indicates that the terminal equipment was on-hook when ring-tip was
detected during ringing. This usually indicates a failure in the terminal equipment or the
type of terminal has a low ringer impedance. Call the terminal equipment and verify that
the terminal rings. If the terminal does not ring, then replace it. Otherwise, enter the test
port location command, and follow the procedure for Test #48.
Aux Data 40977 indicates that terminal equipment was not connected when ringing was
attempted. Run the short test using the test port location command, and follow
the procedure for the results of Test #48.
c. Error Type 15: A software audit error that does not indicate hardware malfunction. Run the
short test sequence, and investigate associated errors.
d. Error Type 257: An in-line error and can only be resolved over time. This error indicates
that ringing voltage is absent. If only one analog circuit pack in the system has this problem,
then replace the circuit pack. If only analog circuit packs on a particular carrier have this
error, then the ringing generator may not be connected to this carrier. If analog circuit packs
on many carriers have this error, then it is probably a problem with the ringing generator.
18 0 busyout
station
extension
WRN ON release station extension
257 (d
) 40973 none
513 (e
) Station Present
test (#48)
WRN OFF test port location sh r 2
769 Battery Feed test
(#35)
MIN
WRN
1
ON test port location sh r 2
2817 (f
) Hyperactive MIN OFF