AUX-TRK (Auxiliary Trunk)
Issue 1 June 2005 661
Notes:
a. Error Type 0: Run the short test sequence first. If every test passes, run the long test
sequence. Refer to each appropriate test’s description, and follow its recommended
procedures.
b. *Error Type 1 with Aux Data 57481 indicates a port fault. Use an empty port if one is
available until the circuit pack can be replaced.
c. Error Type 1 or 769 with Aux Data 57482 indicates a fault on signaling lead, which is an
off-board error. This error should only occur with loudspeaker paging. If the trunk is being
used for another application, check that the administration is correct. Otherwise, check the
wiring to the external equipment connected to the Auxiliary Trunk and check the external
equipment.
d. Error Type 15: software audit error that does not indicate any hardware malfunction. Run
short test sequence, and investigate associated errors.
e. Error Type 130: the circuit pack has been removed or has been insane for more than 11
minutes. To clear the error, reseat or replace the circuit pack.
18 0 busyout port
location
WRN OFF release port location
130(e
None WRN ON test trunk grp#/mem#
sh
769(c
) 57482 None
257 Hybrid/Conference MIN
WRN
1
ON test port location l
r 3
Circuit test (#33)
513 NPE Crosstalk test (#6) MIN
WRN
2
ON test port location l
r 3
1025 Diagnostic: Auxiliary Trunk
(#114)
WRN ON test port location sh
r 3
1. Major or Minor alarms may be downgraded to Warning alarms based on the values used in set options.
Table 223: Auxiliary Trunk Error Log Entries (continued)
Error
Type
Aux
Data
Associated Test Alarm
Level
On/Off
Board
Test to Clear Value
2 of 2