CO-TRK (Analog CO Trunk)
Issue 1 June 2005 839
Notes:
a. Error Type 0: Run the short test sequence first. If every test passes, run the long test
sequence. Refer to each appropriate test’s description, and follow its recommended
procedures.
b. These are in-line errors that have no specific test associated with them. Numerous Error
Types have these errors. Refer to Table 287: CO Trunk Errors with No Tests
on page 840
for an explanation and appropriate action.
c. Error Type 15: software audit error that does not indicate any hardware malfunction. Run
short test sequence, and investigate associated errors.
d. Error Type 130: the circuit pack has been removed or has been insane for at least 11
minutes. To clear the error, reinsert or replace the circuit pack.
e. Numerous Error Types have these errors.
● Aux data 57345: Single polarity ringing current
● Aux data 57376: No loop current on incoming call
● Aux data 57408: No tip ground detected on outgoing call
● Aux data 57424: No loop current on outgoing call
● Aux data 57484: No dial tone on outgoing call
These errors will cause Dial Tone Test #0 to run and are only considered a problem if the
Dial Tone test fails (in which case Error Type 1537 will also show up). In this case, the trunk
may be put in “Ready-for-Service” state (shown as “disconnected” by status command), that
allows only incoming calls. Run Dial Tone Test #0, and follow its outlined procedures.
3073 (e) 57376 None
3329 (e
) 57408 None
3329 (e
) 57484 Dial Tone Test (#0) MAJ
MIN
WRN
OFF test port location l r 1
3585 (e
) 57424 None
The ATMS Transmission Tests are not supported on the G700/G350, and abort with Error Code 1412.
3840 (g
) 8000 Transmission Tests (ATMS)
(#844-848)
OFF test analog-testcall
3841 (g
) Transmission Tests (ATMS)
(#844-848)
MIN OFF test analog-testcall
1. Major alarms may be downgraded to Warning alarms based on the value used in set options.
Table 286: CO Trunk Error Log Entries (continued)
Error
Type
Aux
Data
Associated Test Alarm
Level
On/Off
Board
Test to Clear Value
2 of 2