Media Path PING Test (#1374)
This test is nondestructive.
The test selects a Media Processor board. It then requests the local Media Processor to
execute a PING on the endpoint address. If the PING is successful, the test passes. If the PING
is not successful, the test fails.
Services can execute the standard ping command using the Media Processor board address
and endpoint IP address to see the actual round-trip delay.
This test checks the IP network connectivity needed for audio packets to be sent to the
endpoint.
This nondestructive test runs due to in-line errors, during periodic and schedule maintenance,
and on demand.
Table 462: Test #1374 Media Path PING Test
Error
Code
Test
Result
Description / Recommendation
2100 ABRT Could not locate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals, up to 5 times.
2. Escalate if the problem persists.
2500 ABRT Internal system error.
1. Retry the command at 1-minute intervals, up to 3 times.
2. Escalate if the problem persists.
2806 ABRT No Media Processor board found to use for this test.
ANY FAIL The system could not PING the registered endpoint from a Media
Processor board. This may result in calls with no talk path.
1. If the Registration Status Inquiry test (#1372) fails, follow those
procedures.
2. Refer to MEDPRO, Test #1378, for a detailed description of the error
codes.
PASS PING through this Media Processor is successful.