Communication Manager Maintenance-Object Repair Procedures
400 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
1002 ABRT The system could not allocate time slots for the test. The system may be
under heavy traffic conditions or it may have time slots out-of-service due
to TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy
traffic, retry the command at 1-minute intervals up to 5 times.
1003 ABRT The system could not allocate a tone receiver for the test. The system
may be oversized for the number of Tone Detectors present, or some
Tone Detectors may be out of service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals up
to 5 times.
1004 ABRT The port was seized by a valid call during the test. The test has been
aborted.
1. Use display port location to determine the station extension.
Use status station to determine the service state of the port. If
the port is active, wait until it is idle.
2. Retry the command at 1-minute intervals up to 5 times.
1005 ABRT This test is not run on ports administered as External Alert, Announcement
or combined modem pool ports. This error can be ignored.
1018 ABRT The test has been disabled by administration. The default for the Test
field on the station screen is y. Determine why this field was set to n on
this station. It may be due to the ringing application Test #48, which can
be customer or terminal disturbing.
1. To enable the test for the particular analog station being tested, enter
change station extension.
2. Enter y in the Test field.
Table 118: Test #161 Loop-Around Test (continued)
Error
Code
Test
Result
Description / Recommendation