Communication Manager Maintenance-Object Repair Procedures
1522 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Error Log Entries and Test to Clear Values
5. Replace the circuit pack. Slide the circuit pack into the slot, and lock the latching
lever.
6. Wait for initialization. Wait for:
● the circuit pack to reseat (faceplate LEDs light go
out).
● Windows 2000 boots (PC BOOT appears on the
faceplate LCD).
● IP Trunk application to run (IP TRK # appears on
the faceplate LCD).
Table 549: Replacing the TN802 hard drive (continued)
Step Description Comments
2 of 2
Table 550: MAPD (TN802) Error Log entries
Error
Type
Aux
Data
Associated Test Alarm
Level
On/Off
Board
Test to Clear Value
0 (a) 0 Any Any Any test board location
1 (b
) 0 Circuit pack removed or
SAKI (#53)
MIN
WRN
1
ON
2 (c
)
18 (d
)0 busyout board
location
WRN OFF release board
location
23 (e
)0 WRNOFFadd ds1 location
125 (f
) none 3 None MIN
WRN
2
ON
257 (g
) 65535 Control Channel Loop
(#52)
MIN ON test board location
l r 20
257 (g
) Any None
513 (h
)Any MIN
WRN
3
ON
1 of 3