Communication Manager Maintenance-Object Repair Procedures
2266 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
S8700 MC
Board Type Check Test (#574)
This test verifies that a Tone-Clock circuit pack administered with a Stratum-3 clock source has
code TN780.
Table 812: Test #574 Board Type Check Test
Error
Code
Test
Result
Description / Recommendation
2012 ABRT Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
ANY FAIL Stratum-3 clock synchronization is administered for the carrier where this
Tone-Clock circuit pack resides, but the Tone-Clock does not have code
TN780.
1. If the Stratum-3 clock option is incorrectly administered, remove it.
2. Otherwise, replace the circuit pack. See Replacing the IPSI or
Tone-Clock Circuit Pack on page 2337.
PASS The proper Tone-Clock circuit pack code (TN780) is present for Stratum-3
clock synchronization.