Communication Manager Maintenance-Object Repair Procedures
1706 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Hardware Error Log Entries and Test to Clear Values
Notes:
a. Error Type 0: run the short test sequence first. If every test passes, run the long test
sequence. Refer to each test’s description, and follow its procedures.
b. Error Type 1: the circuit pack has stopped functioning. Reset the circuit pack using
busyout board location, reset board location, and release board
location. If the SAKI Sanity test (#53) passes, the on-board circuitry is healthy. If the
SAKI Sanity test (#53) fails, replace the circuit pack.
Maintenance/Test Board Error Log Entries
Error
Type
Aux
Data
Associated Test Alarm
Level
1
1. Major or Minor alarms on this MO may have been downgraded to Warning based on the values in set
options.
On/Off
Board
Test to Clear Value
0 (a)0 Any AnyAnytest port location sh r 1
1 (b
) 0 SAKI Sanity
test (#53)
MIN ON
18 (c
)0 busyout
board
location
WRN OFF release board location
36 (d
)0
217 (f
)WRNON
257 (e
) 0 CC Loop test
(#52)
MIN ON test board location r3
267 (f
)WRNON
513 (g
) 4352 to
4357
769 (h
) 4358
1025 (i
) 4363 NPE Audit test
(#50)
test board location l
1538 (j
)0 MINON
3840 (k
) 4096 to
4101
3999 (l
) Any None