Communication Manager Maintenance-Object Repair Procedures
2174 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
System Technician-Demanded Tests:
Descriptions and Error Codes
S8700 MC: If Stratum 3 is administered using change synchronization, the Stratum-3 Clock
Alarm Query test (#649) also executes when test synchronization is run. Test #649 is
described in Stratum-3 Synchronization
on page 2146.
Test Synchronization Test (#417)
This test updates every Synchronization Maintenance component with the correct information
about its role in providing a system’s synchronization. This test updates every:
● IPSI circuit pack’s Tone-Clock circuit
● Tone-Clock, Expansion Interface, DS1 Interface, and UDS1 Interface circuit pack in the
system. The test either passes or aborts.
Order of Investigation Short Test
Sequence
Long Test
Sequence
D/ND
Test Synchronization test (#417) X X ND
Table 773: Test Synchronization Test (#417)
Error
Code
Test
Result
Description / Recommendation
Blank ABRT Internal system error
1. Retry the command at 1-minute intervals up to 3 times.
1000 ABRT System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 3 times.
1115 ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2500 ABRT Internal system error
1. Retry the command at 1-minute intervals up to 3 times.
PASS The Synchronization Maintenance component circuit-pack parameters have
been successfully updated. The system should be synchronized after
successful execution of this test. If synchronization problems still exist, refer
to the Error Log to obtain information about the source of the problem.