Communication Manager Maintenance-Object Repair Procedures
1426 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
h. Error Type 3842: Receive FIFO Overflow error. This error occurs when the circuit pack or
media module detects an overflow of its receive buffers. If it occurs frequently, it may
indicate a LAPD parameter mismatch between the two endpoints of a packet-switched
connection. LAPD should be able to recover from this problem, but it may degrade the
performance of the LAN bus. Maintenance will not start any testing or generate any alarms
in response to this error.
i. Error Type 3843: This error occurs when the Signaling Port LAN Loop-Back test (#939)
fails. Run the long test sequence and pay particular attention to the results of Test #939.
G700: For this error type, the associated test aborts with Error Code 1412 on the G700.
System Technician-Demanded Tests:
Descriptions and Error Codes
The command to test the ISDN-LNK MO is test port location where location is 24 for
24-channel interfaces and 16 for 32-channel interfaces.
Signaling Link Board Check (#643)
This test checks the health of the TN464C/D, TN464F/GP UDS1 Interface or MM710 DS1
Interface Media Module transporting the ISDN-PRI Signaling Link port.
Order of Investigation Short Test
Sequence
Long Test
Sequence
D/ND
1
1. D = Destructive; ND = Nondestructive
Signaling Port LAN Loop-Back test (#939)
S8300 / G700: On G700, aborts with Error Code 1412.
XD
Signaling Link Board check (#643) X X ND
Table 512: Test #643 Signaling Link Board Check
Error
Code
Test
Result
Description / Recommendation
ABRT Internal system error
1. Retry the command at 1-minute intervals up to 5 times.