ETH-PT (Control LAN Ethernet)
Issue 1 June 2005 1163
2100 ABRT Could not locate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals, up to 5 times.
2. Escalate if the problem persists.
2500 ABRT Internal system error.
1. Retry the command at 1-minute intervals, up to 3 times.
2. Escalate if the problem persists.
1 FAIL System software indicates at least one Ethernet link session is down
(SOME UP).
1. Isolate downed sessions (status port location or status
link n).
2. Follow actions based on session information.
2 FAIL System software indicates every Ethernet session is down (ALL DOWN).
1. Test the port (test port location) to verify the Ethernet Local
Looparound test (#1278) result.
2. If test passes, wait for system software to indicate ALL UP.
If not, check the destination and other components in the path.
3. If the destination and other components in the path are in service,
take action based on session information.
PASS Every session is up.
Table 400: Test #1286 Session Status Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 2