Communication Manager Maintenance-Object Repair Procedures
2280 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
1003 ABRT The system could not allocate a tone receiver for the test. The
system may be oversized for the number of tone detectors present
or some of the tone detectors may be out of service. Enter list
measurements tone-receiver to display basic information
about the system's tone receivers.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the test at 1-minute intervals up
to 5 times.
1004 ABRT The port was seized by a user for a valid call.
1. Use display port location to determine the trunk group/
member number of the port. Use status trunk to determine
the service state of the port. If the service state indicates that
the port is in use, then the port is unavailable for certain tests.
Wait until the port is idle before retesting.
2. If the port status is idle, retry the command at 1-minute intervals
up to 5 times.
1018 ABRT Test disabled by administration. This only applies to analog
stations.
1. To enable test, set the Test field on the Station Administration
form (change station extension) for the particular analog
station being tested to y.
1020 ABRT The test did not run due to a previously existing error on the specific
port or because of a more general circuit pack error.
1. Examine the Error Log for existing errors against this port or
circuit pack, and attempt to diagnose the previously existing
error.
S8500 / G700:
1412
ABRT This test does not execute on a G700 Media Gateway.
2000 ABRT Response to the test request was not received within the allowable
time period.
1. Retry the command at 1-minute intervals up to 5 times.
Table 816: Test #7 Conference Circuit Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 5