MAPD-BD (MAPD Interface Circuit Pack TN802)
Issue 1 June 2005 1529
Shutting Down NT on the TN802
Before removing the TN802 circuit pack from the carrier, shut Windows NT down first by
following either procedure described in Table 551: Windows NT shutdown procedures
on
page 1529:
System Technician-Demanded Tests:
Descriptions and Error Codes
Investigate tests in the order presented below. Clearing Error Codes associated with the one
test may also clear errors generated from other tests in the sequence.
Table 551: Windows NT shutdown procedures
Step Faceplate button PC interface
1. Push the recessed button on the front
faceplate and hold it in.
Click on the Start button in the lower left
corner.
2. “M shut” flashes on the LCD display Click on Shut Down.
3. When shutdown is complete, “MSHUT
#” displays (“#” is blinking).
Select the Shut down the computer?
radio button.
4. Remove the circuit pack. Click on OK.
5. Wait for the message indicating that
shutdown is complete.
6. Remove the circuit pack.
Order of Investigation Apply to
TN802?
1
Short Test
Sequence
Long Test
Sequence
Reset
Board
Sequence
D/ND
2
NPE Connection Audit test (#50) Y X ND
Control Channel Loop test (#52) Y X ND
Loss of Signal Alarm Inquiry test (#138) N X X ND
Blue Alarm Inquiry test (#139) N X X ND
1 of 2