Communication Manager Maintenance-Object Repair Procedures
1636 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
1 to 17 FAIL The test failed because the MM710 interface Media Module detected
errors in the received framing bits pattern. The Error Code equals the
number of misframes detected by the MM710 interface Media Module
since the last misframe alarm inquiry test. Major bit and minor bit error
rate (error types 2561 and 2817) error logs often accompany misframe
alarms. Clearing the cause of these error logs may clear the misframes
which are occurring.
If the MM710 connects to a T1 network facility or to another switch, do
the following:
1. Retry the command at 1-minute intervals for a maximum of 5 times.
2. Enter list measurement ds1-log GGGVS to read the error
seconds measurement.
3. Verify that both endpoints of the DS1 link are administered using
the same signaling mode, framing mode, and line coding.
4. Check the physical connectivity of the MM710 interface Media
Modules and the cable.
5. Replace the local MM710 interface Media Module, and repeat the
test.
6. Contact T1 Network Service or the technician at the remote switch
to diagnose the remote DS1 endpoint.
Table 599: TEST #145 Misframe Alarm Inquiry Test (continued)
Error
Code
Test
Result
Description/ Recommendation
2 of 4