Layer 3 Query Test (#1243)
This test is nondestructive.
This test is used to check the application layer communications across the in-service ISDN
D-Channel. The test passes if a status enquiry message is successfully sent, fails if the
signaling link is down, and aborts if a query is already running or there is an internal error.
Table 825: TEST #1243 Layer 3 Query
Error
Code
Test
Result
Description/ Recommendation
1005 ABRT The test aborted due to a configuration problem. This test may not be
applicable, or it may be disruptive to terminal equipment other than a voice
terminal (for example, a modem pool member or Music on Hold). This error
can be ignored.
1019 ABRT Test is already running.
1113 ABRT The signaling link is down.
1. Use the test port GGGVSpp long command to clear any errors
which prevent establishment of the signaling link.
2. Examine the results of Test #626, which is executed with the command.
If this test aborts or fails, follow the repair procedure for the Signaling
Link Status Test.
3. Escalate problem if BRI Layer 3 Query Test continues to abort.
1139 ABRT The Packet Bus in the port network is out-of-service.
1. Follow the repair procedures for the Packet Bus.
2. After completing Step 1, execute the test port GGGVSpp command
and review the results of the BRI Port Local LAN Looparound Test to
verify the repair.
1141 ABRT The PKT-CTRL is out-of-service.
1. Consult the repair procedure for PKT-CTRL.
2. If Step 1 does not resolve the problem, escalate to the next tier.
1144 ABRT The Processor Port Network Packet Bus is out-of-service.
1. Follow the repair procedures for the Packet Bus.
2. After completing Step 1, execute the test port GGGVSpp long
command and review the results of the BRI Port Local LAN Looparound
Test to verify the repair.