Communication Manager Maintenance-Object Repair Procedures
2114 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
1281 Any 7 Failure audit (#777) MAJ
MIN
WRN
OFF test board location r 1
1537 Any 8 Failure audit (#777) MAJ
MIN
WRN
OFF test board location r 1
1793 Any 9 Failure audit (#777) MAJ
MIN
WRN
OFF test board location r 1
2049 Any 13 Failure audit (#777) MAJ
MIN
WRN
OFF test board location r 1
2305 Any 14 Failure audit (#777) MAJ
MIN
WRN
OFF test board location r 1
2561 Any 15 Failure audit (#777) MAJ
MIN
WRN
OFF test board location r 1
2817 Any 16 Failure audit (#777) MAJ
MIN
WRN
OFF test board location r 1
3073 Any 17 Failure audit (#777) MAJ
MIN
WRN
OFF test board location r 1
3329 Any 18 Failure audit (#777) MAJ
MIN
WRN
OFF test board location r 1
3585 Any 19 Failure audit (#777) MAJ
MIN
WRN
OFF test board location r 1
3841 Any 20 Failure audit (#777) MAJ
MIN
WRN
OFF test board location r 1
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each
appropriate test’s description, and follow its recommended procedures.
2. The slot location of the SNI at the other end of the peer link indicted by the SNI reporting the error.
Table 757: SNI-PEER Hardware Error Log Entries (continued)
Error
Type
Aux
Data
SNI
Slot
1
Associated Test Alarm
Level
On/Off
Board
Test to Clear Value
2 of 2