POWER
Issue 1 June 2005 1875
4 FAIL The battery is currently being charged.
1. After 30 hours, the battery should be fully charged, and this error
should clear.
2. If after 30 hours the battery is still in the high charge rate, an alarm
will be raised. Use display errors to see the Error Log, and
select the category “environs” to show only environment-related
errors. Look for POWER errors of type 257. The first occurrence of
this error indicates the time when the battery started charging. Use
this time as the starting point to determine whether the battery has
been charging for 30 hours. If so, then replace the battery and
battery charger.
!
CAUTION:
CAUTION: Read the section, Replacing the Battery and Battery
Charger (J58890CE) on page 1870 before proceeding.
3. Rerun the test. If the test still fails, then the PN’s MAINT
(Maintenance) circuit pack could be reporting this condition
incorrectly. There are failures that can occur on the PN’s
Maintenance circuit pack that will not be detected by their
respective maintenance, but which will cause many, if not every,
environment test to fail. If many environment tests are failing, the
suspect circuit pack, depending on the system configuration,
should be replaced and the test rerun. Resolve every alarm on
these MOs, and rerun the test.
6 FAIL This indicates that Error Codes 2 and 4 occurred. Refer to these
descriptions. Also, refer to this test’s description for Error Code 14.
Table 684: Test #5 Battery and Battery Charger Query Test (continued)
Error
Code
Test
Result
Description / Recommendation
3 of 5