Communication Manager Maintenance-Object Repair Procedures
838 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Error Log Entries and Test to Clear Values
Table 286: CO Trunk Error Log Entries
Error
Type
Aux
Data
Associated Test Alarm
Level
On/Off
Board
Test to Clear Value
0 (a
)0 Any AnyAnytest port location sh r 1
1 (b
) 57347 None
15 (c
) any Port Audit Update (#36)
18 0 busyout trunk WRN OFF release trunk grp#/mem#
130 (d
) None WRN ON test port location sh r 2
257 (b
) 50176 None
513 (b
) 57364 None MAJ
MIN
WRN
1
ON
769 (b
) 57392 None MAJ
MIN
WRN1
OFF
1025 (f
) Any Demand Diagnostic (#3) MAJ
MIN
WRN1
OFF test port location sh r 2
1281 (f
) Any Demand Diagnostic (#3) MAJ
MIN
WRN1
ON test port location sh r 3
1537 Dial Tone Test (#0) MAJ
MIN
WRN1
OFF test port location l r 2
The next two tests abort on the G700/G350 with Error Code 1412.
1793 Looparound and Conference Test
(#33)
MAJ
MIN
WRN1
ON test port location l r 3
2049 NPE Cross Talk Test (#6) MAJ
MIN
WRN1
ON test port location l r 3
2561 (e
) 57345 None
2817 (b
) 57360 None
2817 (b
) 57393 None
2817 (b
) 57484 Dial Tone Test (#0) MAJ
MIN
WRN
OFF test port location l r 1
1 of 2