Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
Communication Manager Maintenance-Object Repair Procedures
442 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
FAIL The terminal equipment is not connected to the circuit pack. Some
terminal equipment, such as modems, may fail even when connected
properly.
1. Remotely test the terminal equipment.
2. If the test fails again, resolve any RING-GEN errors in the error log, if
present.
3. Check all of the wiring between the station equipment and the switch.
Then, run the test again.
4. If the test still fails, the terminal equipment may be defective. Check
and replace it, if necessary.
5. Some terminal equipment might fail even when it is connected
properly. If this is the case, disable the test using change station
extension (enter n into the Test field). Note that this action also
disables Tests 6, 7, 35, and 161 on this port.
PASS The station is connected properly to the switch. Investigate user-reported
troubles on this port by running other port tests, by examining station wiring,
or by inspecting the station.
Note:
Note: This test may also pass if no terminal equipment is
connected and the terminal is located very far from the
switch.
0
NO
BOARD
The test could not relate the internal ID to the port (no board). This result
could be due to incorrect translations, no board is inserted, an incorrect
board is inserted, or an insane board is inserted.
1. Check to make sure that the board translations are correct. Enter
list configuration, and resolve any problems.
2. If the board is correctly inserted, enter busy board location
3. Enter reset board location
4. Enter release board location
5. Enter test board location long
This should re-establish the link between the internal ID and the port. If not,
verify that a valid board is inserted.
Table 130: Test #48 Station Present Test (continued)
Error
Code
Test
Result
Description / Recommendation
3 of 3