Communication Manager Maintenance-Object Repair Procedures
1758 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
NPE Crosstalk Test (#9)
The NPE Crosstalk test verifies that this port’s NPE channel talks on the selected time slot and
never crosses over to time slots reserved for other connections. If the NPE is not working
correctly, one-way and noisy connections may be observed. If a secondary data module is
assigned, it is tested after the primary data module. If either test fails, both data modules are
taken out of service. This test usually run only during the long test sequence and takes about 20
to 30 seconds to complete.
Port Circuit Information Channel and Control Channel
Loop-Around (#13)
G700: Aborts with Error Code 1412 on a G700 Media
Gateway.
XND
Data Module Audits test (#17) X X ND
1. D = Destructive; ND = Nondestructive
Order of Investigation Short Test
Sequence
Long Test
Sequence
D/ND
1
2 of 2
Table 651: Test #9 NPE Crosstalk Test
Error
Code
Test
Result
Description / Recommendation
1 ABRT During testing of the primary information channel, system resources may
not have been available.
1. Check the port status. Use display port location to determine
the station extension of the port. Use the status station
command to determine the service state of the port. If the service
state indicates that the port is in use, then the port is unavailable for
this test. You must wait until the port is idle.
2. If the port status is idle, then retry the command at one-minute
intervals a maximum of 5 times.
1 of 3