AN-LN-PT (Analog Line Port)
Issue 1 June 2005 445
2000 ABRT Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals up to 5 times.
2100 ABRT System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
FAIL The reflective loop-around test failed. This could cause noisy or unreliable
connections, or users calling this port may hear an echo. The problem can
also be off-board.
1. Since a line seizure may affect the test, repeat the test at 1-minute
intervals up to 5 times.
2. Use test board location short to run circuit pack tests to check
the Tone Generator and the Tone Detector circuits on the IPSIs or the
Tone Generator/Tone Detector circuit packs.
3. Resolve any problems on the Tone Generator or the Tone Detector
circuit.
4. If the Tone Generator and Tone Detector circuits are functioning
properly, determine whether a voice terminal is connected and wired
properly. Resolve any problems found.
5. If the test still fails, replace the analog line circuit pack.
PASS The port provides an analog transmission path to the station equipment.
Investigate user-reported troubles on this port by running other port tests, by
examining station wiring, or by inspecting the station.
Table 131: Test #161 Analog Looparound Test (continued)
Error
Code
Test
Result
Description / Recommendation