Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
CO-TRK (Analog CO Trunk)
Issue 1 June 2005 853
1002 ABRT The system could not allocate time slots for the test. The system may be
under heavy traffic conditions or it may have time slots out-of-service due
to TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy
traffic, retry the command at 1-minute intervals up to 5 times.
1003 ABRT The system could not allocate a tone receiver for the test. The system
may be oversized for the number of Tone Detectors present, or some
Tone Detectors may be out of service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals up
to 5 times.
1004 ABRT System resources required to run this test are not available. The port may
be busy with a valid call.
1. Use display port location to determine the trunk group/
member number of the port. Use status trunk to determine the
service state of the port. If the port is active, wait until it is idle before
testing.
2. If the port status is idle, retry the command at 1-minute intervals up to
5 times.
1018 ABRT The test was disabled by administration. Verify that the Maintenance
Test field on the Trunk Group screen is set to n. To enable the test, use
change trunk-group <x>, where <x> equals the number of the trunk
group to be tested. Change the Maintenance Test field on the screen to
y.
1. Retry the command at 1-minute intervals up to 5 times.
S8300 /
G700
1412
ABRT This test does not execute on a G700 media gateway.
2000 ABRT Response to the test was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
2100 ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
Table 291: Test #33 Looparound and Conference Circuit Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 4