Communication Manager Maintenance-Object Repair Procedures
1234 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
5016
5017
5018
5019
5032
5033
5048
5064
5080
5096
5112
FAIL Initialization failure: the EI circuit pack reset successfully and restarted
execution, but the EI circuit pack detected communication errors during
hardware initialization. The nature of the failure may prevent the EI circuit
pack from communicating with its neighbor EI circuit pack on the opposite
end of the fiber. The fault itself may be either on the EI circuit pack or on
the lightwave transceiver.
1. If every other test on this EI circuit pack is passing and no other errors
have been logged against this circuit pack, replacement of the
lightwave transceiver or the circuit pack is recommended, but not
critical.
2. If some tests on this EI circuit pack are failing or other errors have been
logged against this circuit pack, replace the lightwave transceiver and/
or the EI circuit pack.
PASS The EI was successfully reset, and it restarted execution. It also passed all
of its initialization tests and detected a lightwave transceiver. Remove the
EI circuit pack from the busyout state by using release board PCSS.
1. Execute test board PCSS short. Refer to errors for each test.
0
NO
BOARD
No board was detected by the test.
1. Resolve either wrong board (Error 125) or no board (Error 131) issues.
2. Check that the board is properly translated and inserted. If so, check
for hyperactivity (Error 1538). If hyperactive, use reset board
location.
3. Run the test again. If it fails, the ID chip on board may be bad. Replace
the board and retest.
Table 417: Test #224 Expansion Interface Test (continued)
Error
Code
Test
Result
Description / Recommendation
5 of 5