Communication Manager Maintenance-Object Repair Procedures
2086 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
118 FAIL The SNI circuit pack cannot communicate with the equipped SNI in slot
18.
1. Perform the Fiber link fault isolation
procedure in Maintenance
Procedures (03-300192). This will resolve multiple SNI-PEER errors.
2. If the SNI being tested has SNI-PEER Error Type 3329, replace the
SNI being tested. Replacing an SNI may be service interrupting. See
SNI-BD (SNI Circuit Pack)
on page 2046 for the procedure for
replacing an SNI. To view SNI-PEER errors, use display errors
with category PNC-PEER. Retry the command.
3. If the SNI being tested has SNI-PEER Error Type 3329, replace the
SNI in slot 18. Replacing an SNI may be service interrupting. See
SNI-BD (SNI Circuit Pack)
on page 2046 for the procedure for
replacing an SNI. Retry the command.
119 FAIL The SNI circuit pack cannot communicate with the equipped SNI in slot
19.
1. Perform the Fiber link fault isolation
procedure in Maintenance
Procedures (03-300192). This will resolve multiple SNI-PEER errors.
2. If the SNI being tested has SNI-PEER Error Type 3585, replace the
SNI being tested. Replacing an SNI may be service interrupting. See
SNI-BD (SNI Circuit Pack)
on page 2046 for the procedure for
replacing an SNI. To view SNI-PEER errors, use display errors
with category PNC-PEER. Retry the command.
3. If the SNI being tested has SNI-PEER Error Type 3585, replace the
SNI in slot 19. Replacing an SNI may be service interrupting. See
SNI-BD (SNI Circuit Pack)
on page 2046 for the procedure for
replacing an SNI. Retry the command.
Table 752: TEST #759 Configuration Audit (continued)
Error
Code
Test
Result
Description / Recommendation
10 of 13