Communication Manager Maintenance-Object Repair Procedures
2218 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
The Pending Activation state indicates a problem with the channels, the wiring, or the TBRI-BD
circuit pack. When in this state, the Level 1 interface is either not receiving any L1 framing from
the channel, or it is communicating with the channel but cannot transition to the Activated state.
The Deactivated state indicates a problem with the TBRI-BD circuit pack. When in this state, the
Level 1 interface is not active, and an idle signal is transmitted to the channels or that Layer 1
was deactivated by the switch. When an TBRI-PT port is placed in the out-of-service state,
Level 1 is also put into the Deactivated state. This could be due either to the system detecting a
fault with the port or to a busyout port location request.
Table 793: Test #1242 Level 1 Status Query
Error
Code
Test
Result
Description / Recommendation
1187 ABRT The board or port may be busied out.
1. Look in the Error Log for Error Type 18 (port busied out) for this
port and TBRI-BD (board busied out). If this Error Type is
present for TBRI-PT only, then release the port with release
port location and run the test again. If the error is present
for both TBRI-BD and TBRI-PT, then release the board with
release board location and run the test again.
When you release a board, you release every port associated with it.
If certain ports still need to be busied out, use busyout port
location to busy them out.
2. Make sure the endpoint is connected.
3. Retry the command at 1-minute intervals up to 5 times.
S8300 / G700:
1412
ABRT This test does not execute on a G700 media gateway.
2000 ABRT Response to the test was not received from the circuit pack within
the allowable time period.
1. If the test aborts repeatedly up to 5 times, reset the circuit pack
with busyout board location, reset board location,
and release board location.
2. If the test aborts again, replace the circuit pack.
2012 ABRT Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
2100 ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1 of 3