Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
DIG-LINE (Digital Line)
Issue 1 June 2005 941
1003 ABRT The system could not allocate a tone receiver for the test. The system may
be oversized for the number of Tone Detectors present, or some Tone
Detectors may be out of service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals up
to 5 times.
1004 ABRT The port was seized by a valid call during the test. The test has been
aborted.
1. Enter display port location to determine the station extension
or attendant number of the port. Use status station or status
attendant to determine the service state of the port. If the port is in
use, wait until it is idle before testing. Attendants are always in use
(off-hook) if the handset is plugged in and the port is not busied out.
1020 ABRT Test disabled by background testing. Use status station to determine
when station is available for testing.
S8300 /
G700
1412
ABRT This test does not execute on a G700 media gateway.
2000 ABRT Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals up to 5 times.
1
2
FAIL The Network Processing Element (NPE) of the tested port was transmitting
in error.
Error code 1 = Crosstalk test failed on the primary channel.
Error code 2 = Crosstalk test failed on the secondary channel.
1. Replace circuit pack.
PASS The port is correctly using its allocated time slots.
1. To verify that this is not an intermittent problem, repeat this test up to
10 times.
2. If complaints persist, examine the station, connections, and wiring.
Table 321: Test #9 Digital Line NPE Crosstalk Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 2