TBRI-PT (ISDN Trunk-Side BRI Port)
Issue 1 June 2005 2207
System Technician-Demanded Tests:
Descriptions and Error Codes
Investigate tests in the order presented below. Clearing Error Codes associated with the one
test may also clear errors generated from other tests in the sequence.
62 subscription Service not authorized
63 admin/sub Service/option not available
65 admin/sub Bearer capability not implemented
66 admin/sub Channel type not implemented
69 admin/sub Requested facility not implemented
70 admin/sub Only restricted digital BC available
79 admin Service/option not implemented
88 admin Incompatible destination
102 switch
problems
Recovery on timer expired
Table 786: Aux Data Values for Error 3841–3942 (continued)
Aux Data
Value
Type of
Problem
Meaning
2 of 2
Order of Investigation Short Test
Sequence
Long Test
Sequence
D/ND
1
BRI Local LAN Port Loop Around test (#618)
S8300 / G700: Aborts with Error Code 1412 on a G700
XD
BRI TDM Port Loop Around test (#619)
S8300 / G700: Aborts with Error Code 1412 on a G700
XD
L1 Status Query test (#1242)
S8300 / G700: Aborts with Error Code 1412 on a G700
XXD
CRC Error Counter test (#623) X ND
Receive FIFO Overflow test (#625) X ND
Layer 3 Query test (#1243) X ND