Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
Communication Manager Maintenance-Object Repair Procedures
2084 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
114 FAIL The SNI circuit pack cannot communicate with the equipped SNI in slot
14.
1. Perform the Fiber link fault isolation
procedure in Maintenance
Procedures (03-300192). This will resolve multiple SNI-PEER errors.
2. If the SNI being tested has SNI-PEER Error Type 2305, replace the
SNI being tested. Replacing an SNI may be service interrupting. See
SNC-BD (Switch Node Clock Circuit Pack)
on page 2000 for the
procedure for replacing an SNI. To view SNI-PEER errors, use
display errors with category PNC-PEER. Retry the command.
3. If the SNI being tested has SNI-PEER Error Type 2305, replace the
SNI in slot 14. Replacing an SNI may be service interrupting. See
SNI-BD (SNI Circuit Pack)
on page 2046 for the procedure for
replacing an SNI. Retry the command.
115 FAIL The SNI circuit pack cannot communicate with the equipped SNI in slot
15.
1. Perform the Fiber link fault isolation
procedure in Maintenance
Procedures (03-300192). This will resolve multiple SNI-PEER errors.
2. If the SNI being tested has SNI-PEER Error Type 2561, replace the
SNI being tested. Replacing an SNI may be service interrupting. See
SNI-BD (SNI Circuit Pack)
on page 2046 for the procedure for
replacing an SNI. To view SNI-PEER errors, use display errors
with category PNC-PEER. Retry the command.
3. If the SNI being tested has SNI-PEER Error Type 2561, replace the
SNI in slot 15. Replacing an SNI may be service interrupting. See
SNI-BD (SNI Circuit Pack)
on page 2046 for the procedure for
replacing an SNI. Retry the command.
Table 752: TEST #759 Configuration Audit (continued)
Error
Code
Test
Result
Description / Recommendation
8 of 13