Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
Communication Manager Maintenance-Object Repair Procedures
2312 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
1002 ABRT The system could not allocate time slots for the test. The system may be
under heavy traffic conditions or it may have time slots out-of-service due
to TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
repeat test at 1-minute intervals up to 5 times.
1003 ABRT The system could not allocate a tone receiver for the test. The system may
be oversized force.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals up
to 5 times.
1004 ABRT The port was seized by a valid call during the test. The test has been
aborted. Use display trunk-group xx to determine the trunk group/
member number of the port. Use status trunk to determine the service
state of the port. If the service state indicates that the port is in use, then the
port is unavailable for certain tests. Wait until the port is idle before
retesting.
1018 ABRT The test has been disabled by administration.
1. Verify that the Maintenance Test field on the Trunk Group screen is n.
To enable the test, use change trunk-group x where x is the
number of the trunk group to be tested, and enter y in the
Maintenance Test field.
2000 ABRT Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals up to 5 times.
2100 ABRT Could not allocate the necessary system resources to run this test. This
could be due to a failure to seize the port.
1. Retry the command at 1-minute intervals up to 5 times.
Table 830: Test #33 Looparound and Conference Circuit Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 4