ATM-TRK (Circuit Emulation Service Circuit Pack)
Issue 1 June 2005 621
Notes:
a. Error Type 1: the ATM-TRK circuit pack does not appear to be in its assigned slot.
1. Make sure that the ATM-TRK circuit pack is installed correctly seated in the slot
administered for the ATM trunk.
b. Error Type 18: the ATM circuit pack is busied out.
1. Run release board location.
c. Error Type 23: an ATM trunk is administered, but the corresponding ATM-TRK circuit pack
does not appear to be physically installed.
1. Make sure the ATM-TRK circuit pack is installed and correctly seated in the slot.
d. Error Type 125: an ATM trunk is administered but a non-ATM-TRK circuit pack is installed
in the corresponding slot. You have two options:
● Replace the incorrect circuit pack with an ATM-TRK circuit pack.
● Or re-administer the slot for the circuit pack that is physically present, locate the slot
where the ATM-TRK circuit pack is actually installed, and re-administer the ATM trunk.
e. Error Type 257: Control Channel Loop test (#52) failed. The circuit pack is not properly
connected with the control channel on the TDM bus.
1. Take the corrective action specified by Test #52.
f. Error Type 513: ATM Crosstalk test (#1298) failed. The board is writing to or reading from
a TDM time slot that is not allocated to the board, or the Digital Signal Processor (DSP)
selected for this test has malfunctioned.
1. Run test board location.
2. Take the corrective action specified for Test #1298.
2818(p
)1-24 WRN
/ MIN
ON test board location
3330(q
)3 MIN OFF
3585(r
) ATM Board Error Query
(#1259)
WRN
/ MIN
ON test board location l
3841(s
) Any None
3842(t
) 11 None
3843 (u
) None
3999(v
) Any None
Table 208: ATM-TRK Error Log entries (continued)
Error
Type
Aux
Data
Associated Test Alarm
Level
On/Off
Board
Test to Clear Value
2 of 2