Communication Manager Maintenance-Object Repair Procedures
1554 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Error Log Entries and Test to Clear Values
Notes:
a. Error Type 0: Run the short test sequence first. If every test passes, run the long test
sequence. Refer to each test’s description and follow its procedures.
b. Error Type 1: For the TN802B only, less than three DSPs are OOS (out of service), and no
alarm is raised. The Aux Data field contains the number of DSPs that are OOS.
c. Error Type 18: the MEDPRO has been busied out by busyout port location.
1. Release the port (release port location).
d. Error Type 258: For the TN802B only, more than three, but less than 9 DSPs are OOS (out
of service), and a WARNING alarm is raised. The Aux Data field contains the number of
DSPs that are OOS.
e. Error Type 513: For the TN2302 and TN2602 only, the port is OOS (out of service) because
an associated DSP is bad.
Table 572: MEDPROPT Error Log Entries
Error
Type
Aux
Data
Associated Test Alarm
Level
On/Off
Board
Test to Clear Value
0 (a
)0Any AnyAnytest board location
1 (b
) Any DSP Capacity test
(#1382)
ON test board location l r
5
18 (c
)0 busyout port
location
WRN OFF release port location
258 (d
) Any DSP Capacity test
(#1382)
WRN ON test board location l r
5
513 (e
) DSP Capacity test
(#1382)
MIN ON test port location
515 (f
) Any DSP Capacity Query
test (#1382)
MIN ON test board location l r
5
769 Any TDM NIC
Loop-Around test
(#1380)
MIN ON test port location l r
10
1025 (g
)Any