Communication Manager Maintenance-Object Repair Procedures
1590 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Notes:
a. Error Type 0: run the short test sequence first. If every test passes, run the long test
sequence. Refer to each test’s description, and follow its procedures.
b. Error Type 1: the circuit pack stopped functioning or is physically removed from the system.
This alarm logs approximately 11 minutes after removing the circuit pack and/or the SAKI
Sanity Test (#53) fails.
If the circuit pack is not in the system, insert a circuit pack in the same slot as the error
indicates. See note (g).
c. Error Type 257: transient communication problems between the switch and this circuit
pack. Execute the test board location command and refer to the repair procedures
for the Control Channel Loop Around Test (#52).
d. Error Type 513: on-board hardware failure. Aux data values correspond to the following
detected errors:
Reset the circuit pack with the busyout board location and reset board
location commands. When reset, the circuit pack executes a set of tests to detect the
presence of any of the faults listed above. Detection of one of these errors during
initialization causes the circuit pack to lock-up and appear insane to the system.
1291 (g
) 4359 Clear Error
Counters
(#270)
MIN ON
3586 (h
)MINOFF
3840 (i
) 4096 to
4101
3842 (j
) 46095
3843 (k
) 46097
Aux Value Detected Error
4352 External RAM error
4353 Internal RAM error
4355 ROM checksum error
4357 Instruction set error
Table 588: MG-BRI Error Log Entries and Test to Clear Values (continued)
Error
Type
Aux
Data
Associated Test Alarm
Level
On/Off
Board
Test to Clear Value
2 of 2