Communication Manager Maintenance-Object Repair Procedures
982 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
1314 (q) Any Far CSU
Loopback test
(#1213)
MIN
WRN
†
OFF test ds1-loop location
end-loopback/span-test
1320 Any Loss of Signal
Alarm Inquiry
(#138)
MIN
WRN
†
OFF test board location
1321 Any Loss of Signal
Alarm Inquiry
(#138)
MIN
WRN
†
OFF test board location
1322 Any Loss of Signal
Alarm Inquiry
(#138)
MIN ON test board location
1323 Any Loss of Signal
Alarm Inquiry
(#138)
MIN
WRN
†
OFF test board location
1324 Any Loss of Signal
Alarm Inquiry
(#138)
WRN OFF test board location
1538 (r
)Any MINON
1793 Any Blue Alarm
Inquiry test (#139)
MAJ
MIN
WRN*
*
OFF test board location
1794 Any Blue Alarm
Inquiry test (#139)
MAJ
MIN
WRN*
*
OFF test board location
1795 Any Blue Alarm
Inquiry test (#139)
MAJ
MIN
WRN*
*
OFF test board location
2049 Any Red Alarm Inquiry
test (#140)
MIN
WRN
†
OFF test board location
2305 Any Yellow Alarm
Inquiry test (#141)
MIN OFF test board location
Table 338: DS1 Interface Circuit Pack Maintenance Error Log Entries (continued)
Error
Type
Aux
Data
Associated Test Alarm
Level
On/Off
Board
Test to Clear Value
3 of 4