ANL-16-L (16-Port Analog Line)
Issue 1 June 2005 397
Station Present Test (or Ringing Application Test) (#48)
This test applies momentary ringing voltage to the terminal equipment and monitors resulting
current flow to determine whether terminal equipment is connected to the port. This test may
cause some terminal equipment to ring briefly during daily maintenance. If this ringing disturbs
the customer or the terminal equipment, you can disable it via the Tests field on the change
station screen. However, on some software releases, Tests #6, 7, 161, and 35 are disabled.
Table 117: Test #48 Station Present Test
Error
Code
Test
Result
Description / Recommendation
ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1000 ABRT System resources required to run this test are not available. The port may
be busy with a valid call.
1. If the port status is idle, then retry the command at 1-minute intervals a
maximum of 5 times.
1004 ABRT The port was seized by a valid call during the test. The test has been
aborted.
1. Use display port location to determine the station extension.
2. Use status station to determine the service state of the port. If
the service state indicates that the port is active, wait until it is idle.
3. Retry the command at 1-minute intervals up to 5 times.
1005 ABRT The test was aborted due to a configuration problem. This test may not be
applicable, or it may be disruptive to terminal equipment other than a voice
terminal (for example, the modem pool member or Music On Hold).
1008 ABRT Could not allocate a ringing circuit. Either every ringing circuit is active or
the ringing generator is either defective or incorrectly wired.
Retry the command at 1-minute intervals up to 5 times.
1. If the test continues to abort, look for RING-GEN errors in the Error
Log. If an ABORT 1008 occurs for this test on other circuit packs as
well, then the ringing generator may be defective or is incorrectly
wired. If it does not occur on other ports, then all four ring phases are
active.
1 of 3