Communication Manager Maintenance-Object Repair Procedures
2544 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Error Log Entries and Test to Clear Values
Notes:
a. Error Type 1: the circuit pack or media module stopped functioning or has been physically
removed from the system. This Error Type does not apply to ANN-BD, DETR-BD,
S-SYN-BD, M/T-BD, or CLSFY-BD. The alarm is logged approximately 11 minutes after
removal of the circuit pack or failure of the SAKI Sanity Test (#53).
Check for the physical presence of the circuit pack or media module in the slot indicated by
the alarm. If the circuit pack or media module is absent, insert one of the proper type. If the
circuit pack or media module is present and its red LED is lit, see LED alarms without Alarm
Log entry or with Error Type 1 on page 258.
Table 907: Common Port Circuit Pack Maintenance Error Log Entries
Error
Type
Aux
Data
Associated Test Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each
appropriate test’s description, and follow its recommended procedures.
0Any AnyAnytest board location sh r 1
1 (a
) 0 Circuit pack or Media Module
removed or SAKI Sanity (#53)
MIN ON
18 (b
)0 busyout board location WRN OFF release board location
23 (c
) 0 None WRN OFF
36 (d
) 4368 none
125 (e
) None MIN ON
217 (f
) 0 None WRN ON
257 (g
) 65535 Control Channel Test (#52) MIN ON test board location sh r 20
267 (h
) 0 None WRN ON
513 (i
) Any None MIN ON test board location sh
769 (j
) 4358 None
1025 (k
) 4363 NPE Audit Test (#50) test board location l r 20
1281 (l
) Ringing Application Test (#51) MIN ON test board location r 2
1538 (m
) Any None WRN
MIN
ON
1793 (n
) Neon Test (#220) MIN ON test board location r 2
3840 (o
) Any None
3999 (p
) Any None