Communication Manager Maintenance-Object Repair Procedures
1924 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Station Present Test (or Ringing Application Test) (#48)
This test applies momentary ringing voltage to the terminal equipment and monitors resulting
current flow to determine whether the terminal equipment is connected to the port. The test may
cause some terminal equipment to ring briefly during daily maintenance. If this ringing disturbs
the customer or the terminal equipment, disable it using the Tests field on the Station screen.
However, on some software releases, Test #35 is disabled.
Table 707: Test #48 Station Present Test
Error
Code
Test
Result
Description / Recommendation
ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1000 ABRT System resources required to run this test are not available. The port may
be busy with a valid call. Use display port location to determine the
station extension. Use status station to determine the service state of
the port. If the service state indicates that the port is in use. Wait until the
port is idle.
1. Retry the command at 1-minute intervals up to 5 times.
1004 ABRT The port was seized by a valid call during the test, and the test was
aborted. Use display port location to determine the station
extension. Use status station to determine the service state of the
port. If the service state indicates that the port is in use. Wait until the port is
idle.
1. Retry the command at 1-minute intervals up to 5 times.
1005 ABRT The test was aborted due to a configuration problem. This test may not be
applicable, or it may be disruptive to terminal equipment other than a voice
terminal (for example, the modem pool member or Music On Hold).
1008 ABRT Could not allocate a ringing circuit. Either every ringing circuit is in use, or
the ringing generator is defective or incorrectly wired.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, look for RING-GEN errors in the Error
Log. If an ABORT 1008 occurs for this test on other circuit packs as
well, then the ringing generator may be defective or incorrectly wired
(see errors for RING-GEN). If it does not occur on other ports, then all
four ring phases are in use.