Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
MODEM-PT (Modem Pool Port)
Issue 1 June 2005 1691
2005 ABRT The Maintenance/Test and the Pooled Modem boards’ digital ports failed
to handshake.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test still aborts, replace the Pooled Modem circuit pack.
2312 ABRT The Loop-around test did not complete, failed to receive loop-back data.
1. Retry the test, if still aborts, replace the Pooled Modem board.
2313 ABRT The Maintenance/Test board’s digital port allocated for this test did not
respond to down-linked message.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, replace the MTB.
2314 ABRT The Modem Pool digital port did not respond to downlinked message.
This error is internal to the Modem Pool circuit pack and does not involve
external equipment or interfaces.
1. Busyout the TN758 Pooled Modem conversion resources on the
circuit pack.
2. If the test continues to abort, replace the Pooled Modem circuit pack
and retest.
2500 ABRT Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
2323 ABRT The Maintenance Test circuit pack digital port allocated for this test did not
disconnect properly. This error is more closely related to the Maintenance
Test circuit pack digital port used for this test than the TN758 Pooled
Modem circuit pack itself. Therefore, any hardware testing or replacement
activities will focus on the Maintenance Test circuit pack.
1. Wait 1 minute and attempt the test again up to 5 times.
2324 ABRT The digital portion of the tested Modem Pool port did not disconnect
properly.
1. Wait 1 minute and attempt the test again.
2. If the test continues to abort, replace the Pooled Modem circuit pack
and retest.
Table 624: Test #98 Modem Pool Conversion Resource Loop-Around Test (continued)
Error
Code
Test
Result
Description / Recommendation
3 of 6