ANN-PT (announcement port)
Issue 1 June 2005 469
Hardware error log entries and test to clear values
Notes:
a. Error Type 0: Run the Short Test Sequence first. If all tests pass, run the Long Test
Sequence. Refer to the appropriate test description and follow the recommended
procedures.
b. Error Type 130: the circuit pack has been removed or has been insane for more than 11
minutes. To clear the error, reinsert or replace the circuit pack.
c. Error Type 769 is logged and the port is alarmed when an alarm is raised on the
Announcement circuit pack because of a faulty condition with a common circuit pack
resource. Any one of the following alarmed errors on the Announcement circuit pack causes
this error to be logged against the Announcement Port: 1793, 2049, 2305, 2561. Follow the
ANN-BD (Announcement circuit pack)
maintenance documentation to resolve these alarms.
When the corresponding circuit pack alarm is cleared, this alarm clears.
Table 139: Announcement port error log entries
Error
Type
Aux
data
Associated test Alarm
level
On/
Off
board
Test to clear value
0 (a) 0 Any Any Any test port PCSSpp sh r 1
1 Playback Speech
Memory Array
(PSMA) Test (#206)
MIN ON test port PCSSpp sh r 3
18 0 The port was busied
out
WRN OFF release port PCSSpp
130 (b
) None WRN ON test port PCSSpp sh
257 Channel
Administration
Memory Array
(CAMA) Test (#205)
MINOR ON test port PCSSpp l r 3
17667 In-line error
513 140AY Channel
Sanity Inquiry Test
(#222)
MINOR ON test port PCSSpp sh r 3
17684 In-line error
769 (c
) None